Use the CxFmsConfigCtrl object to display and manipulate an ActiveX CygNet FMS Configuration Control in a CygNet Studio screen environment.
To see an example FMS Configuration Control implemented in a pre-designed screen, open the FMS Config Ctrl.csf file in the CygNet\Clients\CStudio\Screens\Examples folder.
|
Sub btnApply_EventClick() Dim This : Set This = btnApply FmsConfig.SessionNodeTag = editSessionNode.Text FmsConfig.SessionBeginDate = editStartDate.Text FmsConfig.SessionEndDate = editEndDate.Text FmsConfig.SessionDateFormat = cboDateFormat.Selection FmsConfig.PITDateTime = editPIT.Text FmsConfig.UsePIT = checkUsePIT.Check FmsConfig.Apply True End Sub
Sub btnCancel_EventClick() Dim This : Set This = btnCancel FmsConfig.Cancel End Sub
Sub cboDateFormat_EventChange() Dim This : Set This = cboDateFormat FmsConfig.SessionDateFormat = this.Selection End Sub
Sub checkUsePIT_EventChange() Dim This : Set This = checkUsePIT FmsConfig.UsePIT = this.Check editPIT.Enable this.Check End Sub
Sub TheView_EventInitialize() Dim This : Set This = TheView editSessionNode.Text = FmsConfig.SessionNodeTag
editStartDate.Text = FmsConfig.SessionBeginDate editEndDate.Text = FmsConfig.SessionEndDate cboDateFormat.AddString "Device" cboDateFormat.AddString "Contract" cboDateFormat.AddString "Local" cboDateFormat.Selection = FmsConfig.SessionDateFormat
checkUsePIT.Check = FmsConfig.UsePIT editPIT.Text = FmsConfig.PITDateTime editPIT.Enable = FmsConfig.UsePIT End Sub |